AUMA_SGR_05.1–SGR_12.1参数

发布者:沃德科技 发布时间:2014-07-02 阅读:723

Technical data AUMA part-turn actuators for open-close duty SGR 05.1-SGR 12.1
with 1-phase AC motors AUMA NORM

SG 05.1  5.6 – 45  100 150 75 F 05  F 07  25,4  22 22 160 58 19
SG 07.1  11 – 90  120 300 150 F 07  F 10  25,4  22 22 160 58 19
SG 10.1  11 – 90  250 600 300 F 10  F 12  38 30 27 160 107 25
SG 12.1  22 – 180  500 1,200 600 F 12  F 14  50 36 41 160 110 29

General information
Part-turn actuators AUMA NORM require external controls. AUMA offers actuator controls AUMA MATIC AM or AUMATIC AC.
These can also easily be mounted to the actuator at a later date.

Features and functions

Type of duty 4)  Short-time duty S2 - 15 min 
Motors  1-ph AC motor, type IM B14 according to IEC 34 
Insulation class  F, tropicalized 
Motor protection  Standard: Thermoswitches (NC) Option: PTC thermistors (according to DIN 44082) 
Self-locking  yes 
Swing angle  Standard: 80° to 110° adjustable between min. and max. value. Options: 30° – 40°, 40° – 55°, 55° – 80°, 110° – 160°, 160° – 230° or 230° – 320° 
Limit switching  Counter gear mechanism for end positions OPEN and CLOSED Standard: Single switch (1 NC and 1 NO) for each end position Options: Tandem switch (2 NC and 2 NO) for each end position, switches galvanically isolated Triple switch (3 NC and 3 NO) for each end position, switches galvanically isolated Intermediate position switch (DUO limit switching), available for any intermediate position 
Torque switching  Adjustable torque switching for direction OPEN and CLOSE Standard: Single switch (1 NC and 1 NO) for each direction Options: Tandem switch (2 NC and 2 NO) for each direction, switches galvanically isolated 
Non-intrusive setting (option)  Magnetic limit and torque transmitter MWG (only possible in combination with actuator controls AUMATIC) 
Position feedback signal, analogue (options)  Potentiometer or 0/4 – 20 mA (RWG) For further details see separate data sheet 
Torque feedback signal, analogue (option)  Only in combination with magnetic limit and torque transmitter MWG and controls AUMATIC 
Mechanical position indicator  Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED 
Running indication (option)  Blinker transmitter 
Heater in switch compartment  Standard: self-regulating PTC heater, 5 – 20 W, 110 – 250 V AC/DC Options: 24 – 48 V AC/DC or 380 – 400 V AC A resistance type heater (5 W, 24 V DC) is installed in the actuator in combination with the actuator controls AM or AC. 
Motor heater (option)  12.5 W 
Manual operation  Manual drive for setting and emergency operation, handwheel does not rotate during electric operation. Option: Handwheel lockable 
Electrical connection  Plug/socket connector with screw type connection 
Threads for cable glands  Standard: Metric threads Options: Pg-threads, NPT-threads, G-threads 
Terminal plan  KMS 1TP 100/001 (basic version) 
Splined coupling for connection to the valve shaft  Standard: Coupling without bore Options: Machined coupling with bore and keyway, square bore or bore with two-flats according to EN ISO 5211 
Valve attachment  Dimensions according to EN ISO 5211 

1) Tripping torque adjustable for both directions.
2) Permissible average torque for the whole travel of 90°.
3) Weight for part-turn actuator AUMA NORM with 1-phase AC motor, standard electrical connection, unbored coupling and handwheel.
4) Based on 20 °C ambient temperature at an average load with running torque.

We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.

SG 05.1 – SG 12.1
AUMA NORM
Issue 1.05
Y003.651/002/en
Technical data AUMA part-turn actuators for open-close duty
with 1-phase AC motors

Service conditions

Enclosure protection according to EN 60 529 5)  Standard: Options:  IP 67 IP 68 IP 67-DS (Double Sealed) IP 68-DS (Double Sealed) (Double Sealed = terminal compartment additionally sealed against interior) 
Corrosion protection  Standard: Options:  KN KS KX KX-G 
Finish coating  Standard:  two-component iron-mica combination 
Standard colour  Standard: Option:  silver-grey (DB 701, similar to RAL 9007) Other colours are possible on request 
Ambient temperature  Standard: Options:  – 25 °C to + 70 °C – 40 °C to + 60 °C (low temperature) 

Other information

EC directives  Electromagnetic Compatibility (EMC): (89/336/EEC) 
Low Voltage Directive: (73/23/EEC) 
Machinery Directive: (98/37/EC) 
Reference documents  Product description Electric part-turn actuators SG" "
Dimension sheets SG 
Electrical data SG 

Dimensions Part-turn actuators with AUMATIC
integral controls

SG 05.1 – SG 12.1
SGR 05.1 – SGR 12.1
AC 01.2

Dimensions 05.1/AC 01.2 R 05.1/AC 01.2 07.1/AC 01.2 R 07.1/AC 01.2  EN ISO 5211  A A2  A3  AA min.  B1  B2  B31)  B42)  BB min.  BB1 min.  D1  D2  D3  H2  J1 
SGSG F05  40 35 144 30 101 137 190 268 70 90 155 105 160 40 20 150 115 128 275 220 50 150 170
SGSG F07   
SG 10.1/AC 01.2 R 10.1/AC 01.2 12.1/AC 01.2 R 12.1/AC 01.2  F10  63 35 144 30 110.5 172 190 268 70 90 155 105 160 40 20 150 150 153 291 220 56 150 170
SGSGSG F12  80 35 144 30 110.5 172 190 268 70 90 155 105 160 40 20 150 150 170 313 220 70 150 192
Dimensions 05.1/AC 01.2 R 05.1/AC 01.2 07.1/AC 01.2 R 07.1/AC 01.2  K1  L max.  L1  M1  P13)  P23)  P33)  d1 d2 d3  d4  h1 
SGSG 75 60 63 222 349 216 M25 x 1.5  M30 x 1.5  M20 x 1.5  84 225 45 115 32 90 50 M6  9.5
SGSGSGSGSG 55 70 M8  3 13  
SG 10.1/AC 01.2 R 10.1/AC 01.2 12.1/AC 01.2 R 12.1/AC 01.2  75 75  80 100  63 63  222 222  349 349  216 216  M25 x 1.5 M25 x 1.5  M30 x 1.5 M30 x 1.5  M20 x 1.5  84 235 55 115 32 125 70 102 M10  3 17

SG 05.1 – SG 12.1
SGR 05.1 – SGR 12.1
AC 01.2
Y004.691/002/en
Issue 1.11
2/2
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Dimensions coupling according to EN ISO 5211
DIN 6885

Dimensions  SG 05.1 SGR 05.1  SG 07.1 SGR 07.1  SG 10.1 SGR 10.1  SG 12.1 SGR 12.1 
EN ISO 5211  F05  F07  F10  F12 
41.75 51.75 67.6  
b JS9 1)  6 8 10  
d7 H8 2)  18 22 28 36
d7 max.  25.4 38 50  
d9 3)  M5  M6  M6   
L 4  40 65 75  
L 5 3)  8 10 18  
20 35 40  
t 1)  20.8 24.8 31.3 39.3
41.75 51.75 67.6  
d8 min. 2)  18.1 22.2 28.2 36.2
d8 max.  28.2 40.2 4)  48.2  
L 4  40 65 75  
L 6 min.  30 30 30  
20 35 40  
s H11 2)  14 17 22 27
s H11max.  22 30 4)  36  

 

相关资料:AUMA_OPERATION_INSTRUCTONS_MODEL_SG_05.1-SG_12.1_Quarter-Turn_Actuators.pdf

 
  相关阅读
差压变送器的使用注意事项
沃德员工生日福利
E+H公司官方介绍
您的阀门有正确的耐化学品性能吗?
2013年清明节放假通知
网站首页 | 关于我们 | 新闻中心 | 产品中心 | 官方博客 | 联系我们
地址:深圳市福田区深南大道都市阳光名苑大厦2栋27B 电话:0755-82047716 粤ICP备17004566号
优势产品:ASCO电磁阀,UE开关,VEGA物位计,INDUR电机,MAYR离合器,ADI泵
销售一部: 广东、广西、湖南、湖北、河南、福建、贵州、江西、海南、青海点击这里给我发消息

销售二部: 北京、天津、河北、安徽、山东、江苏、浙江、宁夏、四川、内蒙古点击这里给我发消息

销售三部: 上海、重庆、陕西、山西、云南、甘肃、新疆、吉林、辽宁、黑龙江点击这里给我发消息