UEJ402-134真空表压压力开关-0.1-0.14MPa2022-11-24 06:45:23
UEJ402-134真空表压压力开关-0.1-0.14MPa(UE J402-134 Vacuum gauge pressure switch-0.1-0.14MPa )
UE switch debugging method 1. Connect the multimeter to the output wire; 2. Unscrew the screw on the top of the controller; 3. Increase the positive and negative pressure difference to 0.15MPa, which can be read from the standard pressure gauge; 4. Loosen the set screw; 5. Use a straight wrench to turn the set value adjustment screw clockwise to make the set value change from small to large until the switch contact is switched at 0.15MPa; 6. Adjust the pressure of the calibration table to change up and down at 0.6MPa, and check whether it is 0.15Mpa when the pressure drops. This value is the lower switching value to be set. Its corresponding up-switching value is between 0.16-0.17MPa; 7. Tighten the set screw. 8. Debugging completed J402-134 specific parameters series number - model set point adjustable range dead zone overpressure range withstand pressure pressure interface liquid material J402-126 -1.0 to 0 bar 13.5 mbar to 0.1 bar 0.2 bar 0.3 bar 1/4" NPTF Ni Plated Brass-Brass-Zn Plated st J402-134 -1.0 to 1.4 bar 13.5 mbar to 0.1 bar 1.4 bar 1.7 bar 1/4" NPTF Ni Plated Brass-Brass-Zn Plated st J402-144 0 to 1.4 bar 13.8 mbar to 0.1 bar 1.4 bar 1.7 bar 1/4" NPTF Ni Plated Brass-Brass J402-146 0 to 2.1 bar 13.8 mbar to 0.1 bar 2.1 bar 2.8 bar 1/4" NPTF Ni Plated Brass-Brass J402-156 0 to 6.9 bar 27.6 mbar to 0.1 bar 6.9 bar 8.6 bar 1/4" NPTF Ni Plated Brass-Brass J402-164 0 to 13.8 bar 41.4 mbar to 0.3 bar 13.8 bar 13.8 bar 1/4" NPTF Ni Plated Brass-Brass J402-126 Vacuum switch -1bar~0mbar imported UE pressure switchUE working principle The working principle of the pressure switch: when the pressure in the system is higher or lower than the rated safety pressure, the disc in the sensor moves instantaneously, and the switch joint is connected or disconnected by connecting the guide rod. When the pressure drops When it reaches or rises to the rated recovery value, the disc resets instantaneously and the switch automatically resets, or in simple terms, when the measured pressure exceeds the rated value, the free end of the elastic element is displaced, and the switch element is pushed directly or after comparison to change The on-off state of the switch element achieves the purpose of controlling the measured pressure. The elastic components used in the pressure switch include single coil spring tube, diaphragm, bellows and so on. Common models of UE J400 series mechanical pressure switches: UE J402-134 Vacuum pressure switch-0.1-0.14MPa J400 series main models and features J400 type, single point output, internally adjustable J402 type, dual point output, internally adjustable type J403 , three-point output, internally adjustable

注:除UEJ402-134真空表压压力开关-0.1-0.14MPa,更多United Electric(UE)型号欢迎电话或在线联系。
本文出自 深圳沃德科技官网,转载时请注明出处及相应链接。
本文永久链接:https://www.szword.com/zs/ue11737.html
-

PS6X.2SWYDBXATADAHMEXXXXXS,VEGA仪表
PS6X.2SWYDBXATADAHMEXXXXXS...
-

PS6X.2SWYDBXATADAHMEXXXXXS威格VEGA
MET625.CXX...
-

SN61.XXANHKMXX德国VEGA
SN61.XXANHKMXX...
-

B83.AXC53GDSHXKIMXX,VEGA仪表
B83.AXC53GDSHXKIMXX...
-

B83.AXC53GDSHXKIMXX威格VEGA
PSC21.XXXXXGAHB...
-

SWING63.DAFEHXMR 400mm德国VEGA
SWING63.DAFEHXMR 400mm...
-

SWING63.DAFPHXMR 1000mm,VEGA仪表
SWING63.DAFPHXMR 1000mm...
-

SWING63.DAFPHXMR 1000mm威格VEGA
FX81.ACLTBFHXA1AX 3300mm...