燃气压力开关J120-174UE开关2022-11-24 20:02:17
燃气压力开关J120-174UE开关(Gas pressure switch J120-174 US UE switch spot )
Maintenance of gas pressure switch J120-174 US UE switch spot UE switch in use1.In order to avoid damage to the device, the withstand voltage and maximum temperature cannot exceed the range allowed in the specification, even for a short period of time. In operation, it is allowed to reach the maximum pressure and temperature during start-up and test, but in continuous operation, it must be operated strictly according to the data set by the installation range. Prolonged work at maximum pressure and temperature will reduce the life of the sensor. 2. A spare part is very necessary in harsh environment applications, such as the damage of components may endanger life and property, or the loss of control of high and low limits will cause the system to crash. 3. Attention must be paid to the selection of the range of the controller to ensure that the wrong selection of the set value under unintentional or even intentional circumstances will not cause hidden dangers to the system safety. 4. Where shocks, shocks or large temperature changes will not damage or affect the controller, but in damp locations seal the entry point to prevent moisture from entering. 5. It is forbidden to change or modify components after shipment. If it is necessary to change, you must first consult with UE company. 6. Pay attention to the monitoring of the components, and pay attention to whether the components have set point drift or display errors. If so, check the components immediately. 7. It is important to perform preventive maintenance and regular inspections of components to check for damage that could endanger property and personnel. 8. For all components, the factory settings must be checked before use. 9. The rated power specified in the manual must not be exceeded. Overloading will damage components. The wire unit must be selected and installed according to local or international standards. 10. Do not install the component in an environment where the ambient temperature exceeds the range specified in the manual. Qin control inventory UE explosion-proof pressure switch modelJ120-171 J120-172 J120-172 J120-173 J120-174J120-S156B J120-S134B J120-S126B J120-358 J120-190 J120-191 J120-192 J120-193 J120-194 J120-701 J120-702 J120-703 J120-704 J120-5605 H121 - S15 174 physical map

注:除燃气压力开关J120-174UE开关,更多United Electric(UE)型号欢迎电话或在线联系。
本文出自 深圳沃德科技官网,转载时请注明出处及相应链接。
本文永久链接:https://www.szword.com/zs/ue4823.html
-

PS6X.2SWYDBXATADAHMEXXXXXS,VEGA仪表
PS6X.2SWYDBXATADAHMEXXXXXS...
-

PS6X.2SWYDBXATADAHMEXXXXXS威格VEGA
MET625.CXX...
-

SN61.XXANHKMXX德国VEGA
SN61.XXANHKMXX...
-

B83.AXC53GDSHXKIMXX,VEGA仪表
B83.AXC53GDSHXKIMXX...
-

B83.AXC53GDSHXKIMXX威格VEGA
PSC21.XXXXXGAHB...
-

SWING63.DAFEHXMR 400mm德国VEGA
SWING63.DAFEHXMR 400mm...
-

SWING63.DAFPHXMR 1000mm,VEGA仪表
SWING63.DAFPHXMR 1000mm...
-

SWING63.DAFPHXMR 1000mm威格VEGA
FX81.ACLTBFHXA1AX 3300mm...





