0755-82047716

E400-3BS-M201进口UE温度开关2022-11-22 18:38:40

E400-3BS-M201进口UE温度开关(E400-3BS-M201 Imported UE temperature switch )

 

E400-3BS-M201 Imported UE temperature switch UE temperature switch with temperature bulb and capillary introduction Temperature switch with capillary. One end of the capillary is connected to a temperature bulb, which is the temperature-sensing part of the meter, and the other end of the capillary is connected to the display part of the meter (for a remote thermometer), or the execution part (for a temperature switch). Take the remote measurement thermometer as an example to illustrate its working principle: the temperature bulb is filled with a medium (liquid or gas), and using the principle of medium thermal expansion, the pressure generated by the expansion of the medium is transmitted to the display part of the instrument through the capillary tube, and the display of the instrument The part is essentially the watch core of a pressure gauge, which makes the switch move according to the pressure generated by the medium at different temperatures. Principle In-line type: the insertion depth of the switch is slightly less than or equal to the insertion depth provided by the user. Capillary type: the length of the temperature bulb should be less than or equal to the insertion depth provided by the customer, and the length of the temperature package plus the capillary tube is greater than or equal to the length of the temperature package plus the capillary tube provided by the user. Type selection must add code W050 (movable ferrule thread)US UE temperature switch (in-line, capillary)general selection parameters: medium, maximum temperature, set value/adjustable range, explosion-proof in- line type : Insertion depth, installation threadCapillary type: Insertion depth, capillary length, installation thread  400 series temperature switch model description B400, single point output, in-line type, internal adjustment with reference scaleB402, two-point output, in-line type, internal adjustment With reference scaleB403, three-point output, in-line, internal adjustment With reference scaleC400, single-point output, in-line, internal adjustmentC402, two-point output, in-line, internal adjustmentC403, three-point output, in-line Type, internal adjustmentB400-120 B400-121 B402-120 B402-121B403-120 B403-121C400-120 C400-121 C402-120 C402-121 C403-120 C403-121E400 type, single point output, temperature bulb and capillary tube type, internal adjustment with reference scale;E402 type, double point output,;type, three-point output, temperature bulb and capillary type, internal adjustment with reference scale;E400-2BSA E400-2BSB E400-3BS E400-4BS E400-5BS E400-8BSE402 -2BSA E402-2BSB E402-3BS E402-4BS E402-5BS E402-8BS E403-2BSAE403-2BSB E403-3BS E403-4BS E403-5BS E403-8BS 

 

 

注:除E400-3BS-M201进口UE温度开关,更多United Electric(UE)型号欢迎电话或在线联系。

 

 

本文出自 深圳沃德科技官网,转载时请注明出处及相应链接。

本文永久链接:https://www.szword.com/zs/ue5745.html