0755-82047716

UE防爆开关J120-192J120-1932022-11-28 23:02:57

UE防爆开关J120-192J120-193(American ue explosion-proof pressure switch J120-192 J120-193 )

 

working principle The working principle of the pressure switch: When the pressure in the system is higher or lower than the rated safety pressure, the disc in the sensor moves instantaneously, and the switch joint is connected or disconnected by connecting the guide rod. When the pressure drops or rises When the rated recovery value is reached, the disc resets instantaneously and the switch automatically resets, or in simple terms, when the measured pressure exceeds the rated value, the free end of the elastic element is displaced, and the switch element is pushed directly or after comparison to change the switch element. On-off state to achieve the purpose of controlling the measured pressure. The elastic components used in the pressure switch include single coil spring tube, diaphragm, bellows and so on.   main category Flameproof The pressure switch can be divided into explosion-proof type and flameproof type. The service grade range is Exd II CT1 ~ T6. Imported explosion-proof pressure switches must pass UL, CSA, CE and other international certifications. It can be used in explosive areas and strong corrosive atmosphere environments. Flameproof pressure switches are available in different pressure, differential pressure, vacuum and temperature ranges. Common applications include electric power, petroleum, chemical industry, metallurgy, boiler, food machinery, environmental protection equipment and other industries. Mechanical The mechanical pressure switch is a purely mechanical deformation that causes the action of the micro switch. When the pressure increases, the different sensing pressure components (diaphragm, bellows, piston) will be deformed and will move upwards. Through the mechanical structure such as the railing spring, the uppermost micro switch will be activated to output the electrical signal. related terms Accuracy: A value indicating the degree of precision of the device, including linearity, tolerance, hysteresis, repeatability, etc. At present, the highest precision of Nagano's pressure switch can reach ±0.5%FS, and the model is CB33. Maximum pressure (Max.P): the maximum value of the pressure range. Full Scale (FS): The difference between the maximum and minimum values ​​of the pressure range. Connection difference (dead zone): It refers to the difference between the switch setting action value and the reset value. For example, when the set value is 1MPa and the actual reset value is 0.9MPa, the connection difference is 0.1MPa. Working temperature: refers to the temperature range in which the internal mechanism and sensitive components of the instrument will not undergo continuous deformation during operation. Generally, the recommended operating temperature range of the pressure switch is -5~400C. If the temperature of the medium is too high, it can be considered to add an accessory siphon (filling shape) to achieve the purpose of cooling. SPDT (Single Pole Double Throw): Consists of a normally open, a normally closed contact and a common terminal. DPDT (Double Pole Double Throw): It consists of a symmetrical left and right common terminal, and two sets of normally open and normally closed terminals. Upper limit one contact (normally open): When the pressure rises to the set value, the contact will act and the circuit will be turned on. Lower limit one contact (normally closed): When the pressure drops to the set value, the contact will act and the circuit will be turned on. parameter 

 

 

注:除UE防爆开关J120-192J120-193,更多United Electric(UE)型号欢迎电话或在线联系。

 

 

本文出自 深圳沃德科技官网,转载时请注明出处及相应链接。

本文永久链接:https://www.szword.com/zs/ue58710.html