E121-5BS美国UE防爆温度开关2022-11-22 12:15:47
E121-5BS美国UE防爆温度开关(E121-5BS US UE explosion-proof temperature switch )
US UE explosion-proof temperature switch E121-2BSA US UE temperature switch E121-2BSB US UE explosion-proof temperature switch E121-3BS US UE temperature switch E121-4BS US UE explosion-proof temperature switch E121-5BS US UE temperature switch E121-8BS US UE explosion-proof temperature switch E121-13273 U.S. UE Temperature Switch E121-8BS-6S-6S Model E121: Bulb and capillary; one single pole double throw (SPDT) output; epoxy coated housing; externally adjustable, with reference scale, single conduit E121 Series explosion-proof temperature switch parametersType E121, E121-13273 (HTFP), single switch, bulb and capillary***, external adjustment via reference dial.Type E122, E122-13321 (HTFP), dual switch, bulb and capillary*** , external adjustment via reference dial 2BSA -120 to 100 -84.4 to 37.8 150 65.5 5 5 3/8 x 2 5⁄ 8" 2BSB 30 to 250 -1.1 to 121.1 300 148.9 5 5 3/8 x 2 5⁄ 8" 3BS 100 to 400 37.8 to 204.4 450 232.2 5 5 3/8 x 2 1⁄ 8" 4BS 25 to 100 -3.9 to 37.8 150 65.5 2 1 3/8 x 6 3⁄ 4"5BS -20 to 80 -28.9 to 26.7 130 54.4 2 2 3/8 x 5" 8BS 350 to 640 176.7 to 337.8 690 365.6 5 5 3/8 x 3 1⁄ 4" 13273 25 to 325 -3.9 to 162.8 362 5 182 5 1/4" x 10 1⁄ 4" (Heat Tracing) with Capillary Temperature Switch Model C120-120 C120-121 B121-120 B121-121 E121-4BS E121-5BS E121-8BS E121-13273 B122-120 B122-121 E121-3BS E122-8BS B122-13322 E121-2BSA E121-2BSB F120-1BS F120-2BS F120-3BS F120-4BS E122-5BS E122-13321 B121-13272 F120-5BS F120-6BS F120-7BS F120-8BS E122 2BSA E122-2BSB E122-3BS E122-4BS UE Temperature switch with temperature bulb and capillary Introduction Temperature switch with capillary. One end of the capillary is connected to a temperature bulb, which is the temperature-sensing part of the meter, and the other end of the capillary is connected to the display part of the meter (for a remote thermometer), or the execution part (for a temperature switch). Take the remote measurement thermometer as an example to illustrate its working principle: the temperature bulb is filled with a medium (liquid or gas), and using the principle of medium thermal expansion, the pressure generated by the expansion of the medium is transmitted to the display part of the instrument through the capillary tube, and the display of the instrument The part is essentially the watch core of a pressure gauge, which makes the switch move according to the pressure generated by the medium at different temperatures. Dimensions of E121 series explosion-proof temperature switch
注:除E121-5BS美国UE防爆温度开关,更多United Electric(UE)型号欢迎电话或在线联系。
本文出自 深圳沃德科技官网,转载时请注明出处及相应链接。
本文永久链接:https://www.szword.com/zs/ue83288.html
-
G653AD006CA0000过滤器(ASCO)AVENTICS
G653AD006CA0000过滤器(ASCO)AVENTICS...
-
G653A3M060A0000过滤器(ASCO)AVENTICS
G653A3M060A0000过滤器(ASCO)AVENTICS...
-
G653A3M06011100过滤器(ASCO)AVENTICS
G653A3M06011100过滤器(ASCO)AVENTICS...
-
G653A3M050A0000过滤器(ASCO)AVENTICS
G653A3M050A0000过滤器(ASCO)AVENTICS...
-
G653A3M05011100过滤器(ASCO)AVENTICS
G653A3M05011100过滤器(ASCO)AVENTICS...
-
G653A5S660A00F8过滤器(ASCO)AVENTICS
G653A5S660A00F8过滤器(ASCO)AVENTICS...
-
G653A5S660A00F1过滤器(ASCO)AVENTICS
G653A5S660A00F1过滤器(ASCO)AVENTICS...
-
G653A5S650A00F8过滤器(ASCO)AVENTICS
G653A5S650A00F8过滤器(ASCO)AVENTICS...