0755-82047716

原装供应UE压力开关H100-5202022-11-28 09:53:37

原装供应UE压力开关H100-520(Original spot supply US UE pressure switch H100-520 )

 

Original spot supply US UE pressure switch H100-520 H100-521 UE vacuum switch original Trading Co. , Ltd. Diaphragm water column level low pressure and differential pressure switch A variety of optional sensing materials can meet the needs of various corrosive media Smooth and clean stainless steel Sanitary interface Very wide adjustable dead zone can meet the needs of pumps. H100 series UE switch technical parameters: Storage temperature: -54~71℃Ambient temperature: -40~71℃; 520-525.700-706 type: -18~71℃. The ambient temperature changes every 28℃. The typical drift of the set point No more than 1%set point repeatability: Temperature switch: ±1% within the adjustable rangePressure switch 171-174.218.270-376.520-535.700-706.560-564 and other models are ±1% of the adjustable range; 189.483-489.565-567.610-680.490-494 and other models are ±1.5% of adjustable range; all pressure switches have internal set point locking deviceShock resistance: 15G, 10 ms cycle test. Reproducible set pointresistance to vibration : After 2.5G, 5~500HZ vibration test, the set point can be reproduced.Shell: Die-casting aluminum alloy (copper max. 0.6%). With epoxy resin coating. Stainless steel anti-interference scale cover with sealing gasket. Clamping screwEnclosure Rating: Meets NEMA4X.IP65 requirements Switch Output: One Single Pole Double Throw (SPDT) snap action switch. Can be wired as "Normally Open" or "Normally Closed" Electrical Rating: 15 Amps. 125/250/480 VAC Weight: 2 to 7 lbs (varies by model) Electrical connection: 1/2" NPTF port; 2 7/8" diameter punched holes Pressure connection port: 1/4" NPTF; Models are 1/2"NPTF; Models 560-564 have 2" sanitary connections; Models 565-567 have 1 1/2" sanitary connections Temperature Assembly: Bulb and Capillary: 6ft 304 Stainless Steel In -Line: Nickel Plated Brass (standard length). Optional 316L stainless steel. Filling: Non-toxic oil . Temperature Deadband: Under laboratory conditions. Typical value is 1% of set point range for Type F switches. 2% for Type B, C, and E switches. % heat tracing or antifreeze protection thermometer is specially designed for antifreeze protection and other applications. It can be used for ambient environment detection with B100 and E100 type switches. The technical parameters are roughly the same as those listed above. Only the electrical rating of type B100-13546 is 22 Ampere / 480 volts AC switch; E100-13545 switch has an electrical rating of 22 amps / 480V H100 series pressure and temperature switches are very good performance and price switches, widely used in industrial processes and OEM users, integrated design And the shape and structure of the shell make it stronger and more convenient for wiring: the all-weather series switch has a variety of micro switches and a variety of process interface options to meet various requirements.UE pressure switch commonly used models H100-520 H100-521 H100-522 H100-523 H100-524 H100-525 H100-530 H100-531 H100-532 H100-533 H100-534 H100-535 H100-15737 H100-171 H100-172 H100-173 H100-174 H100-560 H100-561 H100-562 H100-563 H100-564-H100 H100-567 H100-701 H100-702 H100-703 H100-704 H100-705 H100-706 H100-190 H100-191 H100-192 H100-193 H100-194 H100-188 H100-189 H100-210 H100-6 612 H100-490 H100-491 H100-492 H100-493H100-15623 H100-15732 H100-15734H100-15735 H100-494 H100-185-185-186 H100 -483 H100-484 H100-485 H100-486 H100-487 H100-488 H100-489 H100-218 H100-270 H100-274 H100-358 H100-376 H100610 H100-10614 H100-616  H100-100-15086 520/521522/523/524/525 selection parameter table 

 

 

注:除原装供应UE压力开关H100-520,更多United Electric(UE)型号欢迎电话或在线联系。

 

 

本文出自 深圳沃德科技官网,转载时请注明出处及相应链接。

本文永久链接:https://www.szword.com/zs/ue85790.html