0755-82047716

美国UE可调死区压力开关H100-157332022-11-24 21:25:38

美国UE可调死区压力开关H100-15733(US UE adjustable dead zone pressure switch H100-15733 )

 

US UE adjustable dead zone pressure switch H100-15733 H100-15731: setting range: 3-30PSI; NBR diaphragm and O-ring, brass pressure port, 1/4"NPTF, maximum pressure 500psi, withstand pressure 600psi.H100-15732:Setting range: 5-100PSI; Butadiene rubber diaphragm and O-ring, brass pressure port, 1/4"NPTF, maximum pressure 500psi, pressure 600psi.H100-15733:Setting range : 9-300PSI; Butadiene rubber diaphragm and O-ring, brass pressure port, 1/4"NPTF, maximum pressure 500psi, pressure 600psi.UE100 series switch featuresH100 type (pressure switch) a single pole double throw (SPDT ) output, NEMA housing, epoxy coating, internally adjustableType H100K (differential pressure switch) one single pole double throw (SPDT) output, NEMA housing, epoxy coating, internally adjustableType B100 (in-line temperature switch) One single pole double throw (SPDT) output, NEMA housing, internally adjustable, with reference scaleC100 type (in-line temperature switch) one single pole double throw (SPDT) output, NEMA housing, internally adjustable, without reference scaleE100 type (type) a single pole double throw (SPDT) output, NEMA shell, internally adjustable, with reference scaleNo reference scaleAmerican UE pressure switch is widely used in high and low pressure protection control of household, commercial, automotive refrigeration systems, steam working conditions and power stations; accumulators, receivers, flash tanks, separators, scrubbers, oil refineries It is also suitable for high and low pressure protection control of various equipment and tools. However, in the selection of pressure switches, the following points must be paid attention to:1. The necessity of explosion protection: explosion-proof forms are divided into flameproof type and intrinsically safe type .2. Do you need to bring instructions: according to customer instructions. 3. Number of contacts: one contact (one output) or two contacts (two outputs). 4. Determination of setting value and pressure range: the recommended setting range is between 30% and 65% of the pressure range, and the settable range is between 15% and 90% of the pressure range. 5. The form of connection difference: adjustable or fixed. 6. Whether there is pulsation: If the pressure pulsates or vibrates, a throttle valve is required to suppress the damage to the instrument caused by the pulsating pressure. 7. Occasions with a diaphragm: When measuring corrosiveness, high viscosity or high temperature, it is necessary to use a diaphragm.

 

 

注:除美国UE可调死区压力开关H100-15733,更多United Electric(UE)型号欢迎电话或在线联系。

 

 

本文出自 深圳沃德科技官网,转载时请注明出处及相应链接。

本文永久链接:https://www.szword.com/zs/ue35423.html